i-on160 Installer Menu Options
Page 51
Type: Active when: Assign to
Partitions?
Part Set D (37) Setting Part Set D. Deactivated on
unsetting Part Set D. (Available only in a
Part Setting system)
No
Set Fail (38) A set command fails. Remains active until
the user acknowledges the set fail.
Yes
Zone Follow
(39)
A specified zone has been triggered. When
you select this type for a zone the display
shows an extra “Follow” option for the
output. Use this option to select the zone
you wish the output to follow. (You can
also follow a “not used” zone or a “Log
Only”.)
No
Zone Alarm (40) The selected zone causes an alarm.
Deactivated when the alarm has been
reset. When programming this output type
the installer can select a specific zone for
the output to follow. (You can follow a “not
used” zone.)
No
Maskin
g
(41) The control unit operates this output
whenever a detector is giving a “mask”
signal (see page 64).
Autoset Warning
(42)
The control unit starts the Calendar Set
Warning period (see page 58). Deactivates
when the system sets, or if a user defers
or cancels the calendar set.
Yes (all
partitions by
default)
User Defined
(43)
The user switches the output on or off from
the keypad, or a remote control. Assign
this output type to any outputs that you
want the user to control.
Note: You cannot assign this output type to
a control unit plug-by-output.
See “Programming User Defined Outputs”
on page 51 for more details.
Yes
Programming User Defined Outputs
Output type 43 allows you to program User Defined Outputs.
User Defined outputs can be activated by one of the following events:
A user presses a button on a remote that has been programmed to activate
a User Defined output.
A user operates the output from the User Menu – Outputs On/Off option.
A user press one of the A, B, C or D keys on a keypad that the installer has
programmed to operate a User Defined output.
The timer associated with the output reaches its on or off time.