i-on160 Introduction
Page 5
Partition Mode. In Partition Mode the i-on160EX provides the equivalent of
20, smaller, independent alarm systems. Each system is a “Partition” of the i-
on160EX. You can allocate any set of zones to each Partition. Each zone can
also belong to more than one Partition. Each Partition can have a Full Set level
and one Part Set level. During programming the installer can allocate keypads,
sounders or outputs to any of the partitions.
System Security Grade
During initial power up (and if you reset a system to factory defaults) the
system provides an opportunity for you to set various system options in one
step in order to program the system for either Security Grade 2 or Security
Grade 3.
Grade 2 The system uses four digit user codes, puts Masking OFF, defaults
User Reset – Tampers to “yes”, and ensures that Tampers are
communicated as Alarms.
Grade 3 The system uses six di
it user codes, puts Maskin
ON, defaults
User Reset – Zone Tampers and User Reset – Zone Alarms to
Installer. The system communicates tampers as tampers, and also
defaults the Omittable zone attribute to “No”.
You can override any of the settings by selecting individual options in other
parts of the Installer Menu. Note that if you do so then the system may no
longer comply with the selected Grade.
User Codes
When using four digit access codes, the default Installer code is “7890” and the
default User01 code is “1234”.
When using six digit access codes the default Installer code is “567890”, and
the default User01 code is “123456”.
System Capacities
Zones 160 max
Outputs 164 max
Partitions: 20 max
Bus devices: 45 max, shared between expanders and keypads
Radio Keypads: 20 max, two per expander
Radio sounders 20 max, two per expander
WAMs 20 max, two per expander
Users: 500 max
Remote Controls 500 max (one per user)
Proximity ta
s 500 max (one per user)
Radio PAs 500 max (one per user)