Installer Menu Options i-on160
Page 48
Type: Active when: Assign to
Partitions?
Panel Battery
Fault (13)
The control unit detects a fault with its
backup battery, OR a zone of type
“External PSU Battery Fault” has been
triggered. If the alert was caused by an
“External PSU Battery Fault” zone then the
control unit deactivates the output when
the zone has been restored and a user has
acknowledges the fault by entering a valid
access code.
If the alert was caused by a fault with the
control unit’s backup battery then the
control unit deactivates the output when it
detects a good battery and a user
acknowledges the alert.
Note: To cause the control unit to check its
backup battery enter and leave the
Installer Menu.
No
External PSU
Low Volts (14)
An external power supply has tri
ered an
External PSU Low Volts zone.
The control unit deactivates the output
when the zone has been restored and a
user has acknowledges the fault by
entering a valid access code.
No
External PSU
Fault (15)
An external power supply fault signal
triggers a Power output fault zone.
The control unit deactivates the output
when the zone has been restored and a
user has acknowledges the fault by
entering a valid access code.
No
Tamper (16) The control unit detects tamper on any the
following devices:
Control unit, lid or wall tamper.
Radio or wired keypad.
Zone type “Tamper” activates.
Detectors or Expanders
Sounders
The control unit deactivates the output
when tamper is reset.
Yes
Zone Omit
(Setting) (17)
The user Omits a zone while setting the
system. The output deactivates when the
control unit restores the zone.
Yes